Py-GC 450 Pyrolysis Desorption Apparatus (touch screen) 

pygc450.png

Product Introduction

Py-GC 350 thermal pyrolysis desorption instrument is a laboratory-specific gas chromatograph developed by Jiapu Instruments with great concentration. It adopts 7-inch color touch screen control, professional chromatograph UI interface design, and intuitively reflects the inlet and column temperature. The internal temperature value of the box and the detector and the value of each detector, as well as the running time, have a one-key cooling function, the operation is simple and intuitive, and it is convenient to use.

This instrument is widely used in many fields such as scientific research and education, petroleum, chemical industry, biochemistry, food safety, medicine and health, environmental monitoring, judicial investigation and so on. The instrument has high test accuracy, good repeatability, and is trustworthy.


Product Characteristics

1. Brand new production technology, redesign the gas source path and internal structure in the instrument, the layout of parts is more reasonable, the signal interference of components is reduced, the detection accuracy is improved, and the stability and durability of the equipment are excellent.

2. It adopts 7-inch color touch screen control, professional chromatograph UI operation interface design, which intuitively reflects the internal temperature value of the injection port, column thermostat, detector, and the value of each detector, as well as the running time, and has a one-key cooling function. Users can set the detection conditions by themselves, which is very convenient to use.

3. The column thermostat adopts a six-channel independent temperature control system, an automatic rear door opening system, a 21-step 21 platform program temperature rise, a fast rise/fall temperature, and a temperature control accuracy of 0.1°C, making the equipment competent for a wide range of sample analysis.

4. The whole machine adopts modular design and can work in parallel with multiple processors. Contains 2 types of injection port modules (capillary column injection port and packed column injection port), 5 types of high-performance detector modules (FID, TCD, ECD, FPD and NPD), which can be installed according to customer requirements. And detector module (six-port valve, ten-port valve gas sampler, headspace sampler, thermal analysis sampler, cracking furnace sampler, methane reformer can be customized), up to 3 sets of injection ports and 4 kinds of detectors, convenient for users to upgrade later. 


Product Parameters Product Parameters

Basic parametersInstrument modelPy-GC 450
The main purpose

For qualitative and quantitative analysis of organic compounds (inorganic gases)

Working environment requirementsTemperature requirement: 15℃—35℃
Humidity requirements: 25%—80%
Power requirements: AC220V±10%, 50Hz
Power requirement0.01℃
Dimensions600×540×455mm
WeightAbout 60kg


HostTemperature control area6 independent temperature control
Circuit designUsing ARM embedded design, internal CAN method, temperature control adopts high frequency 1700 times per second feedback mechanism, higher control accuracy
Display7-inch color touch screen display, Chinese and English switching, intelligent man-machine dialogue
InletCan be equipped with 3 sample injectors (filled injection port, split/splitless capillary injection port)
DetectorUp to 4 detectors (FID, TCD, FPD, ECD, NPD, PID) can be selected
Auxiliary sampling deviceOptional injection valve, headspace sampler, thermal desorption sampler, automatic sampler, etc.
Chromatography softwareTetchrom® full-counter-control network chromatography workstation can automatically obtain the IP and MAC addresses of the chromatograph, and can realize network self-diagnosis. The instrument can be connected to the network to realize software remote update, firmware "one-click update" and other functions
Connection methodNetwork port connection, 485 and other analog output ports can also be selected at the same time, and DCS fast communication and connection of online instruments can be realized through MUDBAS (TCP/IP) protocol
IntelligentIt can automatically retrieve method files and self-check when starting up. When the chromatograph reaches the starting conditions, it will automatically complete heating, ignition, preparation, automatic valve switching, sample preparation, post-processing and upload the data results to the designated DCS, which can easily realize online monitoring. Project requirements
Method storage and method sequenceThe instrument has a large-capacity storage card 8G inside, which can store a large amount of chromatographic methods; the method sequence can be edited at will to determine different items or realize automatic shutdown after the test is completed, and less manual invalid waiting
Power failure protectionThe instrument adopts the power-off protection function, and the setting data is automatically saved at the moment of power-off, and the routine instrument preparations such as automatic heating and ignition can be realized when the power is turned on.
AutomationSupporting 8 external events, each event independently completes the setting and execution of the required parameters 
Quick functionThe instrument has quick test functions such as one-key preparation, one-key cooling, one-key operation and one-key ignition, which greatly saves customers’ invalid waiting time
expandThe design of up to 4 input and output channels can easily start the chromatograph via external equipment or start external events by the chromatograph. Output mode: IO passive contact or 24V output 


Oven
Temperature riseWith rapid heating and cooling function
Oven temperatureAbove room temperature 5°C ~ 450°C (up to -50°C when using liquid CO2, up to -99°C in liquid nitrogen)
Temperature program21 Tier 21 Platform
Maximum heating rate120℃ / min
Temperature setting accuracy0.1℃
Temperature control accuracy0.02℃
Temperature stabilityFor every 1℃ change in ambient temperature, the temperature change of the column oven is less than 0.01℃
Cooling rateDecrease from 350 to 50℃ ≤8min (room temperature 25℃)
Over temperature protection

When the temperature in the column oven is too high, turn on the automatic protection function

Maximum running time9999.99 minutes 


Sampling system Basic parameters

Number of injection ports: up to three independent temperature-controlled injection units (injection ports/valves) can be installed at the same time

Temperature range of the injection port: the highest temperature is 420℃, and the temperature rise is set in 1℃ steps

Types of sampling unit: single/dual packed column injection port, split/splitless injection port, wide-bore injection port

Single/dual packed column injection portFor qualitative and quantitative analysis of organic compounds (inorganic gases)

Shunt/no shunt

Capillary column injection port

Uses: used for sample injection of capillary chromatographic columns, mostly for the determination of trace impurities
Injection valveHigh temperature heating valve box: up to 4 multi-way valves can be controlled, up to 225 degrees


Detector unitBasic parametersFour independent temperature control detectors can be installed at the same time. The gas of the detector is controlled by the manual pressure control system. The data collection rate of the detector is up to 250Hz (4ms).
Flame Ionization Detector (FID)

Maximum operating temperature: 420℃

Method: dual-flow method

Automatic ignition function: military-grade igniter is adopted, and the ignition wire adopts non-exposed design. The service life is 100 times that of conventional ignition wire. 10-year warranty

Detection limit: 5.0 × 10-12g/s (n-hexadecane)

Baseline noise: ≤2 ×10-14A

Baseline drift: ≤1 × 10-13A/30 min (after the instrument is stable for 2 hours)

Dynamic range: 107 

Thermal conductivity detector (TCD)

Maximum operating temperature: 300℃

Method: dual-arm microporous hot wire design

Sensitivity: S value ≥8000mv.ml/mg (benzene)

Baseline noise: ≤10uv

Baseline drift: ≤50uv/30min

Dynamic range: 105

Electron Capture Detector (ECD)

Maximum operating temperature: 400°C

Method: use Ni63 source constant current method

Minimum detection limit: ≤1.0 × 10-13g/s (r-666)

Baseline noise: ≤40uv

Baseline drift ≤100uv/30min

Dynamic range: 104

Flame Photometric Detector (FPD)

Maximum operating temperature: 350°C

Minimum detection limit: ≤1.4×10-12g/s(P), ≤5×10-11g/s(S);

Baseline noise: ≤20uv

Baseline drift ≤50uv/30min

Linear dynamic range: ≥103S, ≥104P; 


Chromatography control software
Tetchrom chromatographyWorkstation is suitable for win7, win10 and other operating systems, and reads sample data from CDF files conforming to A/A (American Society for Analysis) standards

data collection

The self-developed anti-control network chromatographic workstation realizes the simultaneous acquisition and control of three-channel data (software copyright certificate provided)
authority managementIt can realize three-level authority management for operation and maintenance personnel, instrument users and equipment administrators
data transmissionUsing network port communication, the data throughput is faster, and the two-way handshake frequency is higher. The chromatography system with completely independent intellectual property rights has a standard interface of MODBUS/TCP, which can be easily connected with DCS.
Sensitivity1uV*s, dynamic range: 220
TelecommunicationSupport wireless network communication connection
Unattended functionSupport various functions required for automatic online monitoring, such as automatic startup, automatic heating, automatic ignition, automatic bridge flow, automatic sample collection, automatic data processing, automatic data trend graphs, etc.
Automatic calibrationFor customized projects, it can realize the functions of automatic zero, calibration, zero calibration, calibration, etc., and it can also be calibrated regularly.
system securityFully support FDA-21CFR Part11 certification (electronic signature, resume, user password), system suitability test (SST) and system certification tools (IQ/OQ)
Batch processing functionThe batch processing function makes the instrument control, automatic sampler sequence acquisition, automatic integration correction and output report all in one go, simplifying the daily tedious analysis
Data comparisonPowerful post-processing functions, spectrum comparison, re-calibration, data input and output and other functions are all available. "Special attention Online" can get the analysis results online without waiting until the end of the collection


AccessoriesNameQuantityUnit
small and small injection pads50pcs
Graphite pad φ8*φ3*φ76pcs
M10*φ3 gas path nut6pcs
Graphite pad φ6*φ2*74pcs
Graphite pad φ6*φ3*72pcs
Copper sealing ring (φ5)4pcs
Fuse 12A 3pcs
Fuse 5A5pcs
Fuse 10A5pcs
relief valve outlet connectors2pcs
φ3 gas path 0-ring60pcs
M8*φ3 gas path nut20pcs
M8*φ2 gas path nut4pcs
φ3 tee3pcs
Red copper gas circuit copper pipe20meters
Network cable4pcs
Network cable adapter3pcs
Phillips screwdriver20pcs
Wrench 8-101pcs
wrench1pcs
Wrench1pcs
Soap film flow meter1pcs
special workstation for oil chromatography1pcs
set of manual and certificate1pcs

Computer: Lenovo brand computer, model: ThinkCentreE74

Memory: 4G

Processor: dual-core processor

Hard disk: 500G

Optical drive 16 X DVD

Display 18.5 LCD 1 set

1pcs
Color inkjet printer. Model1pcs
Balance (one in ten thousand)1pcs
bottle of high purity nitrogen 1pcs